# HANDOFF **This document is rewritten in place each session. It is state, not a log.** It is the only handoff you need to read. Dated handoffs in `docs/archive/` are historical and are not required reading — do not diff them against this to work out what is true. If something here is wrong, correct it here. Last updated 2026-09-11, after the composer went live behind the proxy. This line used to carry the commit hash of its own rewrite. It cannot: the hash is not known until the commit is made, so the value was always the *previous* commit and section 3 drifted two commits behind without anyone noticing. Date only, from here. --- ## 0. Read these first, in this order This document is not the first thing to read, despite being the handoff. 1. **`docs/PROCESS.md`** — how work is done here: who runs what, on which machine, with which tools. **It constrains everything below.** Reading it eleventh cost this session three sets of instructions the operator could not execute. 2. **`docs/STAGING-STATE.md`** — what is true on the host right now. 3. **`docs/FAILURES.md`** — what has already gone wrong and why. 4. This document — where the code stands. 5. `docs/ACCEPTANCE.md`, `docs/STOCK.md`, `docs/PRECISION.md` — the specifications the code is held to. When documents disagree, `STAGING-STATE.md` wins on facts about the host and `FAILURES.md` wins on what was actually observed. This one is corrected. --- ## 1. Invocation — read before typing anything These are facts, not examples. Getting one wrong produces an error that looks like a problem with the repository or the containers. **`mechcomp` has `nologin` as its shell.** Use `runuser -u mechcomp -- `, which executes directly. **`su - mechcomp` cannot work** and fails with `This account is currently not available` — a message that looks like a broken account and is not. See F-035. **The interpreter is `/var/www/mechcomp/venv/bin/python`, not `python3`.** `Makefile` line 3 sets `PY ?= venv/bin/python`, and `make deps` installs pytest, Shapely, numpy and `mechcomp` itself into that virtualenv. System `python3` has none of them and fails at the first import (F-036). **All repository operations run as `mechcomp`, never root.** The clone is at `/var/www/mechcomp` in CT 100. Never add a git `safe.directory` exception to work around an ownership complaint; fix the ownership (F-008). **`mechcomp`'s home *is* the working tree.** Anything writing to `$HOME` writes into the repository. `.cache/`, `.local/` and `.ssh/` are in `.gitignore` for that reason (F-029). Git identity is set `--local` for the same reason — `--global` would write into the tree. **`verify.sh` is mode `100644`.** Invoke it as `bash tools/reference-toolchain/verify.sh`, never `./tools/...`. **Gitea SSH is port 42022.** Remotes need `ssh://git@host:42022/owner/repo.git`; the `git@host:path` shorthand cannot carry a port. CT 100 pushes with deploy key `srv-b-ct100`. **Deploy *tokens* in Gitea are account-level**, under user Settings. Repository settings offer deploy *keys* only. **Files reach CT 100 by upload, then `pct push`, then `chown`.** `pct push` writes as root, so `pct exec 100 -- chown mechcomp:mechcomp ` immediately after, every time. **Every network command needs an explicit timeout** (F-030). One without hung the operator's shell. **Logs are in `journalctl`**, not `/var/log/`. Proxmox ships without `rsyslog` (F-024). **Long-running jobs go to `systemd-run --unit= --collect`**, not `nohup` or `setsid`. `pct exec` tears those down when it exits; systemd owns the job and the output lands in the journal. **Docker runs as root in CT 100 only.** `mechcomp` cannot reach the daemon. CT 101 has no `keyctl` and cannot run it at all. **Assert the guest is running before interpreting any `pct exec` result** (F-027). A command that fails because the container is stopped otherwise reads as a pass. Useful canonical form: ```bash if [ "$(pct status 100 | awk '{print $2}')" != "running" ]; then echo "CT 100 NOT RUNNING - stop here." else pct exec 100 -- runuser -u mechcomp -- git -C /var/www/mechcomp status --short fi ``` --- ## 2. The operator's constraint **CIVICVS has a shell on `srv-b` and a browser-based file manager. Nothing else.** No workstation git. No SSH into a container. No IDE. No `scp`. Files arrive by upload to `/root/incoming` on `srv-b`; every command runs in that one shell. `pct exec` from that shell reaches all three containers — that is the container path, and it is not a limitation. An assistant that assumes otherwise produces instructions the operator cannot execute. This has happened repeatedly. **Deliver code by upload, not by paste.** A sixty-line heredoc containing em-dashes and nested code fences was mangled by the browser terminal. Everything delivered since as a tarball — with a stated checksum, file list, and what it overwrites — has worked without exception. State what the archive contains, where it expands, and what it overwrites, every time. When a delivery supersedes an earlier one, **ship every file in the set**, not just the changed one, so the resulting state is unambiguous. --- ## 3. Where things stand ### Infrastructure — complete, do not revisit `srv-b`, Proxmox VE 8.4.0, standalone. | CT | Name | Address | Role | |---|---|---|---| | 100 | `mechcomp` | `10.20.0.10` | application, worker, Docker | | 101 | `mcproxy` | `10.20.0.11` | reverse proxy, TLS | | 102 | `kane-fabric` | `10.20.0.12` | **separate project** | All on `vmbr1`, a portless service bridge. `srv-b` is router and bastion: internet → WireGuard → `srv-b` → containers. Containers cannot reach the home LAN and cannot send mail. `ct-baseline.sh` is read-only, runs any time, exits non-zero on divergence. Installed at `/usr/local/sbin/`. Last run: 62 passed, 0 failed. **A property it does not check is not part of the standard** — that is what makes conformance terminate rather than recur. **Settled decisions. Do not reopen any of these:** - **Webmin is the operator's only remote access.** He works from Webmin on `wg-pk`, the WireGuard hub, and from there into the `srv-b` shell — not the other way round. Questioning this wasted a session once and was questioned again on 11 SEP, because the decision had been recorded without the fact it rests on. The fact is above. Do not ask again. - **`dev.infra` does not exist on the internet.** It is a hosts-file name on `srv-b`, CT 100 and CT 101 only, and CT 101's leaf is signed by a local staging CA. Never tell the operator to open a `dev.infra` URL or a `10.20.0.x` address in a browser: `10.20.0.0/24` is a portless bridge with LAN traffic dropped. The public name is `dev.mechcomp.kane-il.us` and it needs `WORK-ORDER-004`. - Backup is deliberately postponed. Entry condition: `ct-baseline.sh` exits 0. Do not raise it again. - `4x` is the end of the N-strap family. - The `--full` toolchain gate's Docker root-ownership hazard is understood and handled by mounting read-only. See §6. - **Accuracy criterion: 0.01 mm over the entire set.** Set by CIVICVS on 20 AUG. This is the standard the software is held to, and it is met with two orders of margin on every dimensional quantity. See `docs/PRECISION.md`. ### The port — COMPLETE Gitea `main` at `a8081e1` before this commit. CT 100 clean and matching. **Suite: 529 passed, 0 failed.** The 30 expected failures are gone, resolved rather than suppressed, by the tolerance model in `docs/ACCEPTANCE.md`. A red `make test` now means something is actually wrong. **The composer is live.** `mechcomp.service` in CT 100 serves it on `10.20.0.10:8770`, behind nginx on CT 101, proven `HTTPS 200` end to end. `mechcomp-placeholder.service` is disabled and retained as the rollback. | Module | Ported from | Contents | |---|---|---| | `geom/primitives.py` | `sb-geom.scad` | **Pure geometry only.** Vectors, degree trig, exact polyline distance, corner-radius derivation, monotone solver. **`Geo` and `Member` are NOT here** — an earlier version of this table said they were, and two modules were read on the strength of it | | `geom/records.py` | `sb-geom.scad` | `Geo`, `Member`, `place`, `local_rect`, sleeve and cavity paths, reach. The other half of `sb-geom` | | `geom/rounding.py` | BOSL2 `92d697c2` | `round_corners`, `_circlecorner`, `arc`, `segs`, `deduplicate`, `path_merge_collinear`, `is_collinear` | | `geom/region.py` | BOSL2 regions | Shapely booleans, nesting-parity decomposition, area, simplicity, hull, mitred offset, cleaning | | `geom/join.py` | `sb-join.scad` | Butt joints, hull caps, fillets, derived bore, ring fit, section assembly | | `geom/report.py` | `sb-report.scad` | Checks-as-values, metrics, five universal checks, `ProfileRejected`, report formatting | | `geom/core.py` | `sb-core.scad` | PROFILE record, failure representation, centred assembly | | `geom/arrangements.py` | `sb-profiles.scad` | Ring, spoke and fin arrangements, all N-generic | | `profiles/_common.py` | both generators | Assembly pipeline and the eight shared base checks | | `profiles/four_x.py` | `strap-beam-4x.scad` | Five profiles, defaults, 4x base checks | | `profiles/three_x.py` | `strap-beam-3x.scad` | Six profiles, defaults, 3x base checks | | `profiles/__init__.py` | — | `build()`, `ProfileRejected`, family registry | | `stock.py` | — | COTS stock descriptor: `RectStock`, `RoundStock`, `Fit`, `Provenance`. A leaf module — imports nothing from `mechcomp`. See `docs/STOCK.md` | | `design_record.py` | — | What a model was made from, at full precision, sufficient to regenerate it. `input_id` and `build_id` | | `svg.py` | — | Cross-section as SVG, separately classed layers for material, cavities and stock | | `web/app.py` | — | The composer. Standard library HTTP server; binding from `/etc/mechcomp/mechcomp.env` | `make deps` is complete in CT 100 and **must not be re-run**. --- ## 4. What to do next **Nothing is blocked. The composer is live and the suite is green; everything below is new capability.** **CIVICVS stated the goal on 22 AUG: he will not print anything that is not fully configurable.** The compiler is a half-visual composer — the T encloses poly pallet straps in a T, the Y takes a metal electrical conduit core at its centre. That reorders what follows, because a fixed-profile STL is not a deliverable he wants. Two consequences: - **The bore is a declared interface**, with a diameter and a fit class, specified by what goes through it. It is not a byproduct of the inside walls. Conduit for the Y, not only rebar. - **The catalogue front end is the product, not a convenience** that comes after export. `ROADMAP.md` §4 orders it third; that ordering predates this and should be read against it. Roadmap items — read `ROADMAP.md` before starting any: - Dihedral parameterisation. If two panels meet at 137°, none of the eleven profiles gives you a member for it. This is the highest-value gap and it blocks a catalogue that could otherwise not serve the reference structure. - Rebar- and conduit-core bore as a declared interface. See above. - **Per-member stock.** This is what the conduit core actually needs. `Geo` is global to a build, so every member is the same rectangular strap by construction and the Y's centre cannot hold something of a different shape. Moving stock from the build to the placement reaches into `join.py` and `arrangements.py`, and it is the first change where the oracle's own geometry is genuinely at risk rather than merely nearby. - **The composer, deepened.** It exists and serves; it does not export anything, persist anything, or show a bill of materials. `payload["defaults"]` is sent to the browser and nothing reads it — dead weight, and it is what made a verification grep lie on 11 SEP. - STL and STEP export. No CAD kernel is installed in CT 100 (§5). - `mechcomp-worker.service`. `src/mechcomp/worker/` is still a 36-byte stub and nothing needs a worker yet. - Nodes (non-prismatic) and panels (sheet). No representation exists for either. **`WORK-ORDER-004` publishes the composer at `dev.mechcomp.kane-il.us`.** It is infrastructure-mode work on `wg-pk`, which this project does not own, so it is an escalation under `PROCESS.md` §7 and not something to drive with command groups. The `srv-b` half needs no change; the single gate is `AllowedIPs` on the hub's peer entry. **Until it closes, CIVICVS cannot see any of this work.** Note for anyone tempted to shortcut a test print: the OpenSCAD reference in `legacy/` does export printable STL today — `sb_extrude_section` does a `linear_sweep` and `legacy/openscad/README.md` documents the invocation. That is not what he asked for, and offering it again would be repeating a mistake already made once. --- ## 5. Facts established by porting ### The public entry point is `mechcomp.profiles`, not `mechcomp.geom` `conftest.py` does `importorskip("mechcomp.profiles")` and requires a `build` attribute. `build(family, profile, params) -> Result` and `ProfileRejected` are exported from `mechcomp.profiles`. Params use the OpenSCAD parameter names unchanged. **`params` carries only a case's overrides.** Everything else comes from the family's declared defaults, which is why those defaults live in the port rather than the test harness. ### Defaults are per-family, not shared `ring_corner_radius_mm` is **2.00 in 3x** and **1.25 in 4x**. The two generators declare their own parameter blocks and they are not identical. Do not assume a value read from one file applies to the other. 4x also declares `rectangle_aspect`, which 3x has no equivalent of, and its base-check list is correspondingly one entry longer. ### Check order is the reporting order The reference reports the **first** failing check, not an aggregate. Base checks run before profile checks, and both run before any geometry is measured — a builder that failed returns an empty profile, and `centred()` on an empty profile has no members to measure. ### Report values are rounded to six significant figures The oracle records what OpenSCAD's `echo` printed — C's `%g` at default precision — not full-precision geometry. `echo_num()` does this; `echo_vec()` handles vectors, which reach the oracle as strings like `'[20.5209, 20.5209, 20.5209]'`. Load-bearing, not cosmetic — and it is now the basis of the tolerance model. Because the oracle holds six significant figures, the last recorded digit of an area near 200 mm² is worth 0.001 mm², and the whole measured disagreement between port and reference is one, two or three units in that place. See `docs/ACCEPTANCE.md`. Historical note, since it was the visible symptom for two sessions: `VOLUME_MM3` ends in `_MM3`, so the old comparison judged it at the lengths tolerance of 1e-4 against a magnitude near 20,000 — 5e-9 relative, demanded of discretised geometry, by accident of key naming. ### Angles are degrees; the arbitrary constants are contract OpenSCAD trigonometry is in degrees. The port keeps degrees throughout with explicit `cos_d`/`sin_d`/`tan_d` so every expression matches its source line. The 44 solver iterations, the 0.999 and 0.98 scale factors, the 0.05/179.95 degree cutoffs and the 1e9 sentinel are reproduced exactly. They produced the frozen values. ### Environment Shapely 2.1.2 on GEOS 3.13.1 — keep these in step, boolean results on near-degenerate geometry can shift between GEOS releases. numpy 2.4.6. Shapely is in `requirements-base.txt`, the 2D path's own dependency set. **No CAD kernel is installed in CT 100.** `cadquery`, `OCP` and `build123d` are all absent, though `requirements-cad.txt` says it is installed by default. That is the strictest environment for developing the 2D path and will matter when STL and STEP export begins. ### What is verified against the reference **Every dimensional quantity is exact to 1e-4 mm across all 123 cases, with no exceptions.** `ENVELOPE_X_MM`, `ENVELOPE_Y_MM`, `MIN_WALL_ACTUAL_MM`, and every profile extra: `AF_*`, `FIN_*`, `SPOKE_*`, `RING_*`, `T_*`. Every count is exact. **All ten rejections fire correctly**, including the bespoke A Frame and T paths, which were written from the join primitives rather than from a shared arrangement. That is strong evidence those two are structurally right. Only `SECTION_AREA_MM2` and its two derivatives ever disagree. See §7. --- ## 6. Probing the reference directly The pinned toolchain image is in CT 100 and OpenSCAD will echo whatever you ask it. This settled F-034 in four exchanges and will settle any later disagreement the same way. **Prefer it to reasoning.** Mount the tree **read-only** and keep the probe on a separate writable mount — Docker runs as root, and a read-write mount against a `mechcomp`-owned tree is the F-033 hazard. A nested single-file mount inside a read-only mount fails with `EXIT=125`; give the probe its own directory. ```bash pct exec 100 -- bash -c 'mkdir -p /tmp/probe && cat > /tmp/probe/p.scad << "EOF" include $fn = 48; g = sb_geo(15.875, 0.508, 1, 0.25, 1.20, 1.20, 1.20, 1.20); echo(str("PROBE=", sb_area([sb_sleeve_path(sb_member(0,0,0), g)]))); EOF docker run --rm -v /var/www/mechcomp:/repo:ro -v /tmp/probe:/probe -w /probe \ mechcomp/reference-toolchain:8.0.0 \ openscad -o /tmp/o.stl --export-format=asciistl p.scad 2>&1 | grep -E "PROBE|ERROR"' ``` `EXIT=1` is normal — STL export fails on 2D geometry, the echoes still arrive. **The oracle itself is stable.** The gate was run on 19 AUG: all 123 cases regenerate byte-identically inside the pinned image, 113 accepted and 10 rejected, the only diff being `frozen` and the hash containing it. `verify.sh --full`'s restore path was broken, is now fixed, and is **still unexercised** (F-033). **Instrumenting the port is equally cheap.** Monkeypatching `mechcomp.geom.rounding._circlecorner` to print its half-angle and segment count turned the F-034 diagnosis from inference into measurement in one command. The module calls it through the module global, so patching the attribute works. --- ## 7. F-034 — measured, decided, closed **The port is exact. The reference is noisy.** That is the opposite of what the entry previously implied, and it changes what can be done about it. `_circlecorner` computes `raw = (90 - angle)/180 * segs(r, None, fn)` and takes `ceil(raw)`. At `$fn = 48` a 90° corner has half-angle 45, and `(90-45)/180*48` is **exactly 12**. A ceiling on an exact integer is a knife edge. Measured: the port prints `half=45 raw=12 ceil=12` at `%.17g` — landing dead on the integer, every call, both families. The reference's arithmetic lands a hair under 45° at some corners, pushing `raw` fractionally above 12 and the ceiling to 13. On Rectangle: **reference envelope 50 vertices, port 48** (`13+13+12+12` against `12×4`). **Do not try to fix this.** Rounding before the ceiling was tried and reverted — it fixes Y exactly and breaks Three-Fin, because Three-Fin has the same asymmetry and the oracle records it. There is nothing to correct on the port's side. ### Scale of the effect 30 of 113 accepted cases affected. 83 exact. Only three keys ever breach: `SECTION_AREA_MM2` (29), `VOLUME_MM3` (30), `MASS_G` (22) — and volume is area ×100, mass is volume ×density/1000, so each case has **one** discrepancy reported three times. **Worst relative error 2.24e-05.** By profile: Three-Fin 9, Y 7, A Frame 5, Rectangle 5, T 1, Four-Fin 1. None on Equilateral, General Triangle, Square, Diamond or Cross. ### Why the test fails when the geometry is fine At `$fn = 48` a chord deviates from its true arc by `r(1 − cos 3.75°)` = `r × 2.1413e-3`: **2.68 µm at r=1.25, 4.28 µm at r=2.00.** The port and the reference differ from *each other* by at most ~0.4 µm. Against the 0.01 mm criterion (§3) that is two orders of margin. The tests fail because `VOLUME_MM3` is compared at 1e-4 **absolute** against a magnitude near 20,000 — demanding 5e-9 relative agreement from discretised geometry. `3x/Y/steel0.79` breaches on `VOLUME_MM3` alone while its area passes: the same discrepancy, judged by two wildly different standards by accident of key naming. ### The options, and the constraint **Do not edit `tolerance` in the oracle JSON.** It is inside the hashed document; `test_integrity_hash` covers everything but `fixtures_sha256`. Editing it breaks that test by design. The change belongs in `test_oracle.py`, which is not hashed: 1. **Scale-aware bounds for the three discretisation-limited keys**, derived from the 0.01 mm criterion and the section perimeter. Most faithful to where the error originates. Recommended. 2. **A relative floor** — pass if within absolute tolerance *or* ~1e-4 relative. Simplest; loosens `SECTION_AREA_MM2` from 0.001 to ~0.02 mm². 3. **Accept 30 known failures.** Honest but `make test` is never green and a real regression hides among them. **Closed 22 AUG.** Option 1's *scope* was kept — the three keys, the change in `test_oracle.py`, the oracle JSON untouched — but its *derivation* was rejected on measurement and replaced. Measuring `|dA| / P`, the boundary displacement that would produce each area discrepancy, gives a maximum of 1.434e-05 mm: one seven-hundredth of the 0.01 mm criterion. A `perimeter × 0.01` bound would have been 1.86 mm² at the smallest section and 4.54 mm² at the largest, between 1,800 and 4,500 times the worst real discrepancy, and would have caught nothing. Perimeter also anti-correlates with the error — the largest discrepancy is at P = 209 mm and the smallest at P = 454 mm — because the error is driven by how many corners tip from 12 segments to 13, not by boundary length. What replaced it: **eight units in the last place of the oracle's six-significant-figure record**, for those three keys only. Worst case uses 37.5% of its bound, mutation-tested before landing. **`docs/ACCEPTANCE.md` is the specification** — read it before touching any tolerance, and note E-4: everything that positions material stays exact at 1e-4 mm and must never be moved into that regime. --- ## 8. Method that has earned its keep **Read the pinned source; do not recall it.** BOSL2 was fetched at `92d697c2856de2fed93a33e858068589cefc2898` and read directly. Every function examined had a detail that mattered and that recollection would have got subtly wrong. The same applied to the generators: reading `sb-profiles.scad` before writing `four_x.py` confirmed the call signatures rather than inferring them from call sites. **Check the invocation before concluding anything about state.** A `su` that failed identically on two commands read as a repository problem and was an invocation problem. That is the F-027 pattern and it cost a session's opening exchange. **Verify your own arithmetic before shipping it.** A claim in `PRECISION.md` that a 50 mm radius needs `facets ≈ 460` was wrong — deviation falls with the *square* of the segment angle, so the count grows with the square root of radius and the answer is 158. A three-line script caught it. **Mutation-test every suite before landing it.** Break the code deliberately and confirm the tests notice. This found real gaps in five of six slices. It also caught a malformed mutation of mine — cutting the cavities twice is idempotent. **A surviving mutation is sometimes a bad mutation, not a test gap.** **Read-only before write.** Every command group where the answer was not certain established the facts first. **One task, one command group, wait for output.** Not a menu of next steps. If you find yourself writing "and also", delete it. --- ## 9. What the project is for Build the capacity to construct real structures — the reference case is a faceted timber shell — from reclaimed and commodity materials, using whatever fabrication is to hand. The compiler makes the pieces computable, qualifiable, and reproducible by someone who was not present when they were designed. **Codes and permitting are out of scope, deliberately.** The project records physical claims, never verdicts. Measure and attest; never adjudicate. Three artifact classes: **members** (prismatic, exist — the eleven profiles), **nodes** (non-prismatic, no representation yet), **panels** (sheet, none yet). **The output must eventually be sealed manifolds and printable STL.** The 2D section is where manifold validity is decided, not downstream in the CAD kernel — `is_region_simple` is already a build-blocking check, and a self-touching outline extrudes into something untessellatable. **`docs/PRECISION.md` states what this compiler does not do**: no assembly layer, no structural analysis of any kind, prismatic shapes only, no toolpaths. That document is scope-locked to additive and subtractive manufacturing. **Requests to widen it should be refused, not accommodated** — see its §10. --- ## 10. Working with this operator He is precise, keeps excellent records, and will tell you directly when you are wrong — including when you are being unhelpful. Take it at face value; it is accurate and it is not personal. **He decides. Bring evidence and a recommendation, then stop.** He has delegated all coding decisions — structure, algorithms, test design — and does not want to be consulted on them. Still bring him scope, provenance, and anything irreversible on the host. He runs every command, so nothing is autonomous regardless. When he says he does not understand something, the writing was unclear. Rewrite it shorter; do not explain it again at greater length. **He watches for scope creep and treats it as the primary risk** — "the greatest enemy of software is not bugs, it's feature-creep". Documents and code are both held to it. When in doubt, narrow. --- ## 11. Open questions, none blocking | # | Question | Owner | |---|---|---| | 1 | Should `wg-pk` narrow `mynetworks` from `10.110.0.0/22` to explicit hosts? | CIVICVS, estate decision (F-025) | | 2 | Backup strategy — USB, IPFS, optical? | CIVICVS | | 3 | Where is the 3+ TB USB disk attached? | CIVICVS | | 4 | Kane Fabric participant mail, send and receive | Cross-project | | 5 | ~~Tolerance model for the three discretisation-limited keys~~ | **Closed 22 AUG.** See §7 and `docs/ACCEPTANCE.md` | | 6 | Is the bore's fit class per-material, or one clearance for all inserts? | CIVICVS — raised by the conduit-core requirement, §4 | | 7 | Public ingress at `dev.mechcomp.kane-il.us` | `WORK-ORDER-004`; CIVICVS executes on `wg-pk` | Question 4 is real and unaddressed. Containers do not send mail by standard and nothing can reach `vmbr1` from outside, so receiving has no path at all. It needs a design conversation, not a configuration change. --- ## 12. Commit log ``` a8081e1 state: the composer replaced the placeholder; open public ingress 14514b0 web: the composer, served behind the existing proxy chain e921cac design record: every build emits one d2827c2 design record: what a model was made from, sufficient to regenerate it 70787ea stock: records delegates to the descriptor, and the descriptor stops gating f5651d3 stock: name the COTS descriptor; the strap becomes the first entry 6836ece tests: close F-034; bound the derived trio at 8 ULP of the oracle record 52d00b5 docs: HANDOFF header commit line moved to b255ebb b255ebb docs: F-034 rewritten from measurement; handoff updated 114189c docs: PRECISION.md -- scope, guarantees and limits, for lay readers 7b3182c port: the 3x and 4x profile catalogues; build() now exists af196a2 docs: one canonical handoff, rewritten in place; F-035 009fcce docs: handoff for the 19 AUG session 86a47c3 rounding: record F-034, arc segment counts tip on the last bit 8d79431 geom: port sb-core and sb-profiles, the N-generic arrangements b101fe6 geom: port sb-report, validation and report formatting ebf02d6 geom: port sb-join, the junction and envelope strategies 38ea024 geom: Shapely-backed region layer 545eee7 geom: port BOSL2 round_corners and path cleanup dfd02a4 geom: port the pure-geometry half of sb-geom b67cc12 verify.sh: reach the restore on the diff branch 1d3eed0 Handover push 6967eef Conformance updates. c7e32d8 Seed repository: rev-8.0.0 reference, frozen oracle, toolchain, test harness ```