Files
mechanical-compiler/docs/STAGING-STATE.md
T
TheRON eb537768ef ENVIRONMENT 5.4: add the DIVERGENCE marker, and record five unmet requirements
The marker vocabulary had six entries - REQ, PREF, PROVEN, ASSUMED, DEFERRED, INSTANCE. They could say how strong a requirement was and where it came from. None could say it was not being met. That gap is why five unmet REQs in this document went unrecorded for weeks: there was no notation to write them in, so nobody wrote them.

DIVERGENCE is added as the seventh, with the rule attached. A REQ that stops being met does not become a PREF and is not rewritten to describe what was built. It stands, the gap is recorded, the correction is owed by the thing. A specification that agrees with whatever exists specifies nothing. No requirement in this revision was lowered.

DIV-001 at section 14 item 11: the AGPL section 13 source link is a numbered constraint the application code will follow, and it is not met on a public deployment. DIV-002 at section 9 twice and section 8.3: the FastAPI control plane, the worker unit and the SQLite queue do not exist, and five declared dependencies are imported by nothing. DIV-003 at sections 1.3 and 5.2: the instance is publicly reachable against three REQs. DIV-004 at section 11: eight declared keys are read by nothing.

Section 11 also gains MECHCOMP_MAX_EXPORT_MM, read by the code since cdde394 and declared nowhere. That is the divergence running the other way and the harder one to notice, because a missing key looks like nothing at all.

Section 5.2 records that the divergence may be a misfiling rather than a violation. WORK-ORDER-004 section 3 says dev abbreviates Mechanical Compiler Developers, that the name is production, and that it appears on printed material. If that reading holds, 5.2 never applied to this instance and 5.3 does. Written as a decision, not a correction.

Section 1.1 gets a note that it was right about CadQuery all along. DIV-005 was opened against this paragraph rather than against HANDOFF section 5, which had it backwards for three weeks.

Section 15 gate 3 now states its status: dependencies, toolchain image and scaffolding all met, worker unit not met, gate does not pass. Section 19 records the port complete since 20 AUG, retained because the rejected cases being part of the contract is why the oracle means anything.

STAGING-STATE specification reference updated from revision 5 to 5.4.

Applied by anchored patcher. The first attempt failed on one anchor - the env block comment column was 35, not 39 - and nothing was written, including the thirteen correct patches. Suite 643 passed, oracle intact. Documentation only.
2026-09-14 04:26:44 -05:00

28 KiB

STAGING-STATE.md

Live state of the Mechanical Compiler staging instance on srv-b.

Updated 2026-09-13, after the documentation audit
Instance Staging / development
Specification ENVIRONMENT.md revision 5.4
Failure log FAILURES.md
Process PROCESS.md — read first
Method Manual, one command group at a time

0. How to use this file

This is the authoritative record of what is true on srv-b. Where it and ENVIRONMENT.md disagree, this file wins for facts and the specification is defective and must be corrected.

Completed and remaining work are in the same document deliberately. They are two halves of one boundary; separating them guarantees they drift.

Read PROCESS.md before your first command. It describes how work is done here — who runs what, on which machine, with which tools. This file describes only what is currently true.

Before any command: read this file, confirm the immediately relevant live state with a read-only command, then issue one command group. If it fails, record it in FAILURES.md before changing anything else.

Production gets its own PRODUCTION-STATE.md. The specification is shared; the state is not.

Acceptance boundary, 2026-08-16

Staging infrastructure is accepted. That claim is narrower than "the application is deployed," and deliberately so. Three subsystems sit outside it and must not be represented as either hidden failures or completed work:

Subsystem Status
Mail alert delivery Accepted 2026-08-17. Delivered end to end, twice, headers captured.
smartd monitoring Accepted 2026-08-17. Four members monitored, four alerts received.
Backup infrastructure Postponed by operator decision — strategy may change

1. Instance values

The srv-b bindings for the parameters in ENVIRONMENT.md.

Host

hostname          srv-b  /  srv-b.dev.infra
platform          Proxmox VE 8.4.0, Debian 12, kernel 6.8.12-9-pve
hardware          HP ProLiant DL360 G7, 2 x Xeon X5650, 24 threads, 31 GiB
storage           P410i, 4 x EG0146FAWHU, RAID 1+0, all members SMART OK
local             directory /var/lib/vz, ~70 GiB free   iso,vztmpl,backup
local-lvm         LVM-thin pve/data, 166.9 GiB          rootdir,images
vmbr0             10.0.0.12/24 on enp3s0f0, gw 10.0.0.1   management, LAN
vmbr1             10.20.0.1/24, bridge-ports none         service, portless
wg0               10.110.0.12/32, peer wg-pk.civicus.us:51820, allowed 10.110.0.0/22
resolver          75.75.75.75, search dev.infra
ip_forward        1
timezone          America/Chicago, NTP active, clock synchronised
systemd           running, zero failed units
spare NICs        enp3s0f1, enp4s0f0, enp4s0f1 — unconfigured, deliberately
template          local:vztmpl/debian-12-standard_12.12-1_amd64.tar.zst

Containers

CT 100 CT 101
hostname mechcomp mcproxy
role application, worker reverse proxy, TLS
features nesting=1,keyctl=1 nesting=1
cores / RAM / swap 16 / 16384 / 4096 2 / 1024 / 512
rootfs 40 GiB local-lvm 8 GiB local-lvm
mp0 60 GiB → /var/lib/mechcomp, backup=0 —
net0 eth0 on vmbr1, 10.20.0.10/24, gw 10.20.0.1 eth0 on vmbr1, 10.20.0.11/24, gw 10.20.0.1
onboot 1 1
Debian 12 bookworm, fully upgraded 12 bookworm, fully upgraded
systemd running, zero failed units running, zero failed units

Neither container has a LAN interface (F-017). Neither has a stale eth1 stanza (F-021) — verified persistent across reboot.

Names and identity

mechanical-compiler.dev.infra   ->  10.20.0.11    (CT 101, the proxy)
mechcomp.dev.infra              ->  10.20.0.10    PVE-generated
mcproxy.dev.infra               ->  10.20.0.11    PVE-generated

ADMIN_USER      sandor, uid 1000, groups sandor + mechcomp(996)
                shell /bin/bash, both containers
authorized key  SHA256:2pNffCscUUW5Wbs9uMepLEvMLKPqUV/7Lpk5tw7iWSY
                matches /root/.ssh/id_rsa.pub on srv-b — bastion, see section 4
service user    mechcomp, uid 999, gid 996
                home /var/www/mechcomp, shell /usr/sbin/nologin

Host NAT, persisted in /etc/iptables/rules.v4

nat POSTROUTING
  -s 10.20.0.0/24 -d 10.0.0.0/24            -j RETURN       # LAN not translated
  -s 10.0.0.0/24                  -o wg0    -j MASQUERADE   # pre-existing
  -s 10.20.0.0/24                 -o wg0    -j MASQUERADE   # containers -> WireGuard
  -s 10.20.0.0/24                 -o vmbr0  -j MASQUERADE   # containers -> internet

filter FORWARD
  -s 10.20.0.0/24 -d 10.110.0.0/22 -p tcp
     -m multiport --dports 25,465,587       -j DROP         # SMTP egress blocked
  -s 10.20.0.0/24 -d 10.20.0.0/24           -j ACCEPT       # container <-> container
  -s 10.20.0.0/24 -d 10.0.0.0/24            -j DROP         # LAN blocked

Rule order is load-bearing. RETURN must precede both service-network masquerades. Live and persisted states match.

Disk monitoring — accepted 2026-08-17

DEVICESCAN finds nothing behind the P410i. Members are addressed explicitly:

/etc/smartd.conf
DEFAULT -a -m root -M exec /usr/share/smartmontools/smartd-runner
/dev/sda -d cciss,0
/dev/sda -d cciss,1
/dev/sda -d cciss,2
/dev/sda -d cciss,3

before:  Monitoring 0 ATA/SATA, 0 SCSI/SAS and 0 NVMe devices
after:   Monitoring 0 ATA/SATA, 4 SCSI/SAS and 0 NVMe devices
unit:    smartmontools.service   (smartd.service is an alias with no journal)
alerts:  4 test alerts generated and received; headers captured
         -M test reverted; permanent config restored and reboot-proven

Physical identity of the four members. This is how a future SMART alert is matched to a caddy:

Member Model Serial
cciss,0 EG0146FAWHU 6SD0LETK0000B05009W1
cciss,1 EG0146FAWHU 3SD3K5P00000905094UN
cciss,2 EG0146FAWHU 3SD3GHJ600009047RRRG
cciss,3 EG0146FAWHU 3SD3GVP800009045X79B

Not yet captured: power-on hours and grown-defect counts. On 2010-vintage drives holding the only instance, those numbers say how much runway remains. smartctl -d cciss,N -A /dev/sda for each member.

TLS

CA        CN = Mechanical Compiler Staging CA   (locally generated)
leaf      CN = mechanical-compiler.dev.infra
          SAN = DNS:mechanical-compiler.dev.infra
validity  2026-08-16 -> 2028-11-18            <-- nothing renews this
trusted   srv-b, CT 100, CT 101
key       root:root 0600 /etc/ssl/mechcomp/server.key

No Kane County Civic Infrastructure CA issuance path exists on srv-b: no trust anchor, no step, no cfssl, no EasyRSA. Proxmox's own CA was deliberately not reused. Replacing this leaf later is two file copies and a reload.

Application environment

/etc/mechcomp/mechcomp.env, root:mechcomp, 0640:

MECHCOMP_ENV=staging
MECHCOMP_BIND=10.20.0.10          # scalar; loopback is NOT bound
MECHCOMP_PORT=8770
MECHCOMP_BASE_URL=https://mechanical-compiler.dev.infra
MECHCOMP_DATA_DIR=/var/lib/mechcomp
MECHCOMP_LOG_LEVEL=info
MECHCOMP_DB_URL=sqlite:////var/lib/mechcomp/db/mechcomp.sqlite3
MECHCOMP_WORKER_CONCURRENCY=4
MECHCOMP_CAD_BACKEND=none
MECHCOMP_ARTIFACT_RETENTION_DAYS=30
MECHCOMP_SECRET_KEY=<generated, not recorded>

Mail — accepted 2026-08-17

srv-b relayhost   [10.110.0.1]:25 over wg0
root alias        sandor@kane-il.us   (postalias verified)
inet_interfaces   loopback-only
delivery path     srv-b -> wg-pk -> mx1 -> kane-il.us
status            DELIVERED end to end, twice, full headers captured
                  queue empty, no bounced or deferred entries

F-023 was proven to be a relay-trust mismatch three hops downstream: mx1 rejected RCPT TO with 554 5.7.1 Access denied because wg-pk's public addresses were absent from its mynetworks. Corrected by adding only those two addresses.

Standing constraints on this path — do not violate:

Host Constraint
kane-il.us Runs YunoHost. Its mail configuration must not be altered. This is why mx1 exists.
mx1.diagnostics.kane-il.us Uses DANE. Its TLS and certificate configuration must not be broken. The mynetworks change is inbound client trust and does not interact with DANE.
wg-pk Must continue relaying to arbitrary external destinations. Hubzilla registration and notification mail depends on it, and the ISP blocks port 25. Do not restrict it by recipient.

Fragility to know about: delivery now depends on Linode not reassigning 198.58.111.109 or 2600:3c00::f03c:92ff:fe42:43d7. If either changes, mail stops silently and the cause is in mx1's mynetworks.

Open exposure — see F-025. The correction authorises wg-pk under permit_mynetworks, which grants relay to any destination. Combined with wg-pk's own mynetworks = 10.110.0.0/22, every tunnel peer — including both containers, which arrive as 10.110.0.12 through the host masquerade — can originate mail as kane-il.us infrastructure. Correction pending decision.

Logging note (F-024): /var/log/mail.log does not exist. Proxmox ships without rsyslog; Postfix logs to journald. Use journalctl -u postfix@-.

Placeholder backend — staging scaffold, not application code

/usr/local/libexec/mechcomp-placeholder.py
/etc/systemd/system/mechcomp-placeholder.service
runs as mechcomp:mechcomp, reads mechcomp.env, binds 10.20.0.10:8770
Restart=on-failure, hardening set applied, enabled at multi-user.target

Exists solely to prove the proxy chain independently of the application. It is removed when the real service arrives.

Retired 2026-09-11. mechcomp-placeholder.service is disabled and stopped. mechcomp.service holds 10.20.0.10:8770 in its place, running /var/www/mechcomp/venv/bin/python -m mechcomp.web as mechcomp, reading /etc/mechcomp/mechcomp.env for its binding. nginx on CT 101 required no change: the real service took the address the placeholder occupied.

The placeholder unit file is left on disk, disabled. It is the rollback: systemctl disable --now mechcomp.service then systemctl enable --now mechcomp-placeholder.service.

Proven end to end from srv-b at commit 14514b0: HTTPS 200 for the page and a real JSON build payload through the TLS chain.

Rollback copies on disk

srv-b     /etc/network/interfaces.before-mechcomp
          /etc/hosts.before-mechcomp
          /etc/hosts.before-svcfqdn
          /etc/iptables/rules.v4.before-svcnat
          /etc/iptables/rules.v4.before-lanblock
          /root/pct-100.before-svcnet
          /root/pct-101.before-svcnet
CT 100    /etc/hosts.before-svcfqdn
          /etc/network/interfaces pre-F-021 copy
CT 101    /etc/hosts.before-svcfqdn
          /etc/network/interfaces pre-F-021 copy

2. Verified

Each line was demonstrated by command output, not inferred.

Host and network

  • vmbr1 created, active, 10.20.0.1/24, portless
  • Duplicate address detection run before each container creation
  • Container to internet reachable (deb.debian.org, gitea.barternetwork.us)
  • Container to WireGuard reachable (10.110.0.1)
  • Container to LAN gateway 10.0.0.1 = 100% packet loss — the requirement
  • Container to srv-b 10.0.0.12 reachable via INPUT path (required, not a leak)
  • Container to container reachable over vmbr1
  • LAN to Proxmox console 10.0.0.12:8006 returns 200, unaffected
  • NAT and FORWARD rules present live and persisted, in correct order
  • Host: running, zero failed units
  • Mail delivered end to end from root on srv-b, twice, headers captured
  • smartd monitoring 4 devices; 4 test alerts delivered and received
  • Container SMTP egress blocked; internet egress and host mail intact
  • Both containers autostart after a host reboot (onboot: 1)

CT 100

  • Debian 12 bookworm, fully upgraded, zero pending
  • en_US.UTF-8 generated and active; America/Chicago
  • running, zero failed units — after reboot (F-021 corrected)
  • /var/lib/mechcomp is a real separate ext4 filesystem
  • Service user mechcomp, home /var/www/mechcomp, correct ownership
  • All four data subdirectories present, mechcomp:mechcomp, 0750
  • mechcomp.env present, root:mechcomp, 0640, secret generated
  • Base packages installed; OpenSCAD, Qt and X11 absent
  • Docker active, overlay2 / systemd, no fallback needed
  • Repository cloned at e85c4f4e, verified as the owning user
  • Python 3.11.2 venv created, owned by mechcomp
  • openssh-server enabled and active
  • mechcomp-placeholder.service enabled, active, reboot-persistent (F-019)
  • Listener on 10.20.0.10:8770 only — not 0.0.0.0

CT 101

  • Debian 12 bookworm, fully upgraded, zero pending
  • en_US.UTF-8 generated and active; America/Chicago
  • running, zero failed units — after reboot (F-021 corrected)
  • nginx 1.22.1, nginx -t passes, enabled and active
  • Only the project vhost enabled; Debian default removed
  • listen 443 ssl default_server on both address families
  • HTTP to HTTPS 301 redirect
  • Local CA created, leaf issued, trusted on all three hosts
  • HTTPS end to end from srv-b, CT 100 and CT 101 without -k
  • X-Forwarded-Proto: https observed at the backend — re-proved after the topology change and again after CT 100's reboot
  • openssh-server enabled and active

3. Remaining — infrastructure

Immediate

Nothing. The infrastructure boundary is accepted.

Deferred by operator decision

Recorded here so they are visually distinct from failures and from forgotten work. None is a defect.

  • wg-pk mynetworks scope (F-025). Estate decision: whether every tunnel peer should originate mail as kane-il.us infrastructure, or only the hosts that legitimately do. Not this project's to change unilaterally.
  • SMART attribute baseline. Power-on hours and grown-defect counts for the four members, so drive age is a known quantity rather than an assumption. smartctl -d cciss,N -A /dev/sda. Read-only, one command.
  • Backup infrastructure, entirely. Postponed 2026-08-16 because the strategy may change, and reaffirmed 2026-08-18 on stronger grounds: a backup of an unverified configuration restores the confusion along with the data. Entry condition: ct-baseline.sh exits 0. Scope when resumed: vzdump job, archive sizing, retention, free-space guard, host-side pull, mechcomp-backup, backup alerting, gold media, 3+ TB redundancy.

One request standing against the postponement: a single manual vzdump of both containers as a point-in-time snapshot before further change. It presupposes nothing about the eventual strategy and yields the archive size that has been an open question since revision 4. Four 2010-vintage disks currently hold the only instance with no monitoring, no alerting and no backup.

Optional, recorded not scheduled

  • Second nameserver line in container resolver configuration, as a mitigation for F-022. One line, no daemon. Deliberately not applied on a single unexplained event.
  • Staging certificate expires 2028-11-18 and nothing renews it.

3b. Container baseline

ct-baseline.sh is the definition of "standard configuration" on this host. It changes nothing, runs any time, and exits 0 only when every container conforms.

last run   2026-08-18
result     62 passed, 0 failed, 3 informational
scope      srv-b, CT 100, CT 101, CT 102

Overdue — see DIV-006. PROCESS.md §9a requires a run after any change to a container or to host firewall rules. Since that run a DNAT rule was added to nat PREROUTING and persisted, and mechcomp-placeholder.service was replaced by mechcomp.service in CT 100. Either the check was run and not recorded, or it was not run. A conformance result with no date after the changes it covers is not evidence.

A property not checked by that script is not part of the standard. That is what makes it terminate. Divergence used to be discovered by asking, one property at a time, whenever something behaved oddly — which never finishes, because nothing stated what "the same" meant. If a property should be uniform, it belongs in the script rather than in someone's memory.

What it asserts, per container: onboot, unprivileged, nesting=1, a single interface on the service bridge, systemd running with zero failed units, one interface stanza, Debian 12, timezone, generated locale, curl, ca-certificates, openssh-server, sshd active, admin account with authorized_keys at 0600, no mail agent, SMTP egress blocked, LAN gateway unreachable. Host-level: systemd health, both firewall rules, smartd device count, bastion key.

Each failure cites the failure entry that established the requirement, so the reason survives the person.

The mail standard

Containers do not send mail. Only srv-b does, and only its own alerts, through [10.110.0.1]:25. A container with a mail agent installed but SMTP egress blocked is the worst case: it queues forever and delivers nothing.

CT 100 and CT 101 were in exactly that state until 2026-08-18 (F-031).

Ownership

The script checks containers belonging to two projects and encodes host requirements neither owns alone (F-032). It is host-level, not Mechanical Compiler property. Suggested home: /usr/local/sbin/ct-baseline.sh on srv-b, with the canonical copy outside this repository.

Relationship to backup

Conformance is a precondition for backup, not a companion to it. A backup taken before 2026-08-18 would have preserved two containers that queue mail forever, and a restore would have faithfully returned them to that state.

Backing up an unverified configuration does not preserve a system; it preserves a state of confusion. The entry condition for backup work is ct-baseline.sh exiting 0 — and it becomes part of restore verification.


3a. Parallel project on this host

Kane Fabric is a separate project sharing srv-b. Each project has its own FQDN and its own container. They share the service bridge, the WireGuard hub and the proxy — that is the whole of the relationship.

An earlier version of this paragraph said Kane Fabric was where SASE, HOA Diagnostics, the Mechanical Compiler and other SASE-consuming projects are implemented. That is not the arrangement: nothing here is implemented on Kane Fabric. SASE was also used without being defined anywhere in this repository. Corrected 2026-09-13 on the operator's statement of the topology.

Repository github.com/git64bit/Kane-Fabric
Container CT 102 kane-fabric
Address 10.20.0.12/24 on vmbr1, gateway 10.20.0.1
Ownership Separate project. Not Mechanical Compiler infrastructure.
Baseline Conforms as of 2026-08-18, verified by ct-baseline.sh

Recorded here for two operational reasons only.

It shares the service network. CT 102 sits on vmbr1 alongside CT 100 and CT 101, so host-level rules scoped to 10.20.0.0/24 apply to it. In particular it inherits the SMTP egress block (F-025) — if Kane Fabric ever needs to send mail, that will present as a Postfix failure with a non-obvious cause.

Host resources are shared, not pooled. Neither project consumes or repurposes the other's containers. Any integration is through an explicit contract, not through co-location on srv-b.

That is no longer true. IDENTITY-CONTRACT.md specifies the identity half of such an interface and CONSUMER_INTERFACE_GATES.md records gates against it. Neither is implemented, so nothing crosses between the two projects today — but an interface is specified, and it is no longer unassumed.


4. Access model

Confirmed: no workstation access from the home LAN is required.

internet -> WireGuard -> srv-b -> containers

srv-b is the bastion, confirmed by the authorized key matching /root/.ssh/id_rsa.pub on the host. Root on the host can pct enter regardless, so SSH adds no privilege — but every path to a container runs through srv-b, which is deliberate.

Direct WireGuard-side access to the catalogue would be a route addition for 10.20.0.0/24 on the hub. Not now.

Superseded 2026-09-11. A public path now exists, and it is not a route.

browser
  -> dev.mechcomp.kane-il.us  A 198.58.111.109
                              AAAA 2600:3c00::f03c:92ff:fe42:43d7
  -> nginx on wg-pk, Let's Encrypt TLS, expires 2026-12-10
  -> proxy_pass http://10.110.0.12:8770   (srv-b's own tunnel address)
  -> DNAT on srv-b  ->  10.20.0.10:8770
  -> mechcomp.service in CT 100

No WireGuard change was made and no route was added. The hub's peer entry for srv-b is still AllowedIPs = 10.110.0.12/32, as all twenty peers are. An earlier plan widened it to carry 10.20.0.0/24; that was abandoned once the hub's own convention was read. Every existing vhost there -- witness.diagnostics.kane-il.us, otium.civicus.us, shell.infra.civicus.us, corpusdb.infra.civicus.us -- proxies to a 10.110.0.x tunnel address directly. Following that pattern removed the only step with a lockout risk.

The rule on srv-b, in nat PREROUTING, persisted:

-A PREROUTING -s 10.110.0.1/32 -d 10.110.0.12/32 -i wg0 \
   -p tcp -m tcp --dport 8770 -j DNAT --to-destination 10.20.0.10:8770

Scoped to source 10.110.0.1 only -- the hub. The other nineteen tunnel peers cannot reach the service network through it. Widening that is one field.

Rollback copy at /etc/iptables/rules.v4.before-mechcomp-dnat. POSTROUTING order was verified unchanged after iptables-save rewrote the file: the RETURN still precedes both masquerades.

curl http://10.110.0.12:8770 from srv-b itself fails, and that is correct. Locally-originated traffic traverses OUTPUT, not PREROUTING, so it never meets the rule. Test from the hub.

Proven 2026-09-11: https 200 over v4 and v6, http returning 301, real build JSON through the full chain, and the mail path unaffected -- a test message from srv-b was delivered to theron@kane-il.us via wg-pk and mx1 after the ruleset was rewritten.

Reopened 2026-09-11 by WORK-ORDER-004. That decision was correct while there was no application to reach. There is one now, and the consequence of the decision is that CIVICVS cannot see it: mechanical-compiler.dev.infra resolves only on srv-b, CT 100 and CT 101, and 10.20.0.0/24 sits behind a portless bridge with LAN traffic dropped.

The srv-b half needs no change, verified 2026-09-11: ip_forward=1, FORWARD policy ACCEPT, a direct route on vmbr1, and none of the three FORWARD rules matches hub-initiated inbound traffic. The single gate is AllowedIPs on the hub's peer entry for srv-b -- WireGuard drops by cryptokey routing before consulting any routing table, so a route without that entry does nothing.

Correction 2026-09-13: that entry is 10.110.0.12/32, as stated earlier in this section and as all twenty peers are. An earlier version of this paragraph gave it as 10.110.0.0/22, which is srv-b's own AllowedIPs for the hub -- section 1 records it. The two ends of one tunnel were conflated, in the paragraph describing the security boundary, four paragraphs after the correct value appears.

No DHCP anywhere. Two containers with fixed addresses on a portless bridge is the entire address space.


5. Application code — delivered

The port is complete, the composer is live, and nothing here is blocked.

This section used to open with a transcribed repository state block: HEAD at the seed commit c7e32d8, tests 3 passed, 236 skipped, and absent the Shapely port itself. All three were true on 2026-08-18 and none was true after 2026-08-20 — while the checklist directly below them was kept current. Facts three weeks apart sat in one section, and the maintained half lent its credibility to the stale half.

Removed rather than corrected. git rev-parse HEAD reports the commit, make test the suite, venv/bin/pip list the environment, git remote -v the remote.

One line in that block was still accurate when it was deleted — the venv's cadquery 2.8.0 — and it was the only correct statement about the CAD kernel anywhere in this repository at the time, HANDOFF.md §5 having said the opposite since 19 AUG. See DIV-005.

None of the following can be honestly completed, and none may be fabricated by provisioning:

  • Dependency install from committed manifests — done 2026-08-18
  • mechcomp.service — done 2026-09-11, deploy/mechcomp.service
  • Deployment configuration under version control — done 2026-09-12. deploy/mechcomp.service and deploy/nginx/mechanical-compiler.conf, imported verbatim and checksum-proven equal to CT 100 and CT 101 at import. The unit had been recorded as delivered at that path on 11 SEP while existing only on the host. mechcomp.env is deliberately not committed — see deploy/README.md
  • mechcomp-worker.service — no worker exists yet; src/mechcomp/worker/ is still a stub
  • Reference toolchain image mechcomp/reference-toolchain:8.0.0 — present in CT 100, image 1a9d9a6853fd, verified 2026-09-13
  • Fixture reproduction against ddd0f154...
  • Application-runtime acceptance — partial. The composer serves, is reachable through CT 101 internally and at https://dev.mechcomp.kane-il.us publicly, and no acceptance criteria have been written for it. Certificate renewal is unattended via certbot and has not yet been observed to succeed for this name; first renewal is due before 2026-12-10.
  • Replacing the placeholder with the real service — done 2026-09-11

Applied 2026-08-18: venv/ is in .gitignore, along with .cache/, .local/, .ssh/, .gitconfig and .lesshst — the service user's home is install_dir, so anything writing to $HOME writes into the working tree (F-029).

The Shapely port completed 2026-08-20 and gates nothing. Items still unchecked above are unchecked on their own merits.


6. Open questions

# Question Blocks
1 Should wg-pk mynetworks narrow to explicit hosts? F-025 estate half
2 What is the backup strategy? all backup work
3 Where is the 3+ TB USB disk attached? gold redundancy step
4 Public ingress for the composer Closed 2026-09-11. Live at https://dev.mechcomp.kane-il.us; see §4
5 shell.infra.civicus.us and corpusdb.infra.civicus.us publish AAAA 2600:3c00:e000:365::, but wg-pk holds 2600:4c00:e000:365:: -- one hex digit apart. Both names are broken for v6-preferring clients. CIVICVS, estate; not this project

All three need CIVICVS.


7. Closed questions

Question Answer
Kane County CA issuance path None on srv-b. Local staging CA generated.
Relay address and authentication 10.110.0.1:25 over wg0, unauthenticated from 10.110.0.12 accepted.
openssh-server present Yes, both containers.
ADMIN_USER / key sandor; root@srv-b key, bastion pattern confirmed.
DHCP pool on 10.0.0.0/24 Not applicable. Containers are not on that network.
Docker storage driver overlay2 / systemd. No fallback needed.
LAN workstation access Not required. WireGuard through srv-b.
MECHCOMP_BIND semantics Scalar, service address only. Loopback not bound.
Why did delivery fail downstream? mx1 relay trust. Proven and corrected (F-023).
Where does Postfix log on this host? journald. No rsyslog, no /var/log/mail.log (F-024).
Should container SMTP egress be blocked? Yes. Implemented and reboot-proven (F-025 project-local half).
Do the containers autostart? Yes, onboot: 1 on all three, proven by host reboot (F-026).
How do files reach a container? Upload to /root/incoming on srv-b, then pct push / pct exec. See PROCESS.md.
How does CT 100 push to Gitea? Deploy key srv-b-ct100, SSH on port 42022, read/write.
Do containers send mail? No. Only srv-b does. See section 3b.